The LOG04 data logger is suitable for several applications such as :
– Flow measurement (VLI and KDO submerged velocity height sensor, UB-V submerged Doppler velocity sensor, Sommer non-contact velocity and height sensor)
– Storm overflow (LSC overflow logger and CSCV3 wired overflow sensor)
– Lift stations (current clamps F0A00066 and F0A00046)
– Physico-chemical probes for water quality monitoring (Conductivity, Dissolved Oxygen, Turbidity, pH, temperature sensor range)
– Rain gauge (RG20 and RG25)
– Connection to electromagnetic flow meters via Modbus
– Fast counting on water meters using a pulse unit
– …
Radio communication and configuration
These data loggers are configured locally by radio (direct connection, no need of activation on the logger) using a HF/USB configuration kit to connect to your laptop. This kit also includes the Avelour software offering quick and easy configuration at each step (measurement period, threshold, conversion, data sending …)
communication by 2G / 3G or 2G / LTE-M / NB-IoT
The LOG03V4 logger measures and records up to 500,000 measurements. It can retrieve data from other Ijinus sensors and loggers present nearby. It will then send all its data to the SCADA according to the chosen transmission mode. You can choose one of the 2 communication cards: either 2G/3G or 2G/4G (LTE-M / NB-IoT)
By choosing a logger with an integrated modem, you can send your data directly to our web platform www.ijitrack.com, or any other server with your SCADA